IGS-4215-8UP2T2S – Industrial 8-Port 10/100/1000T 802.3bt PoE + 2-Port 10/100/1000T + 2-Port 100/1000X SFP Managed Switch
Designed to be installed in heavy industrial environments, the IGS-4215-8UP2T2S is the new member of PLANET Industrial-grade, DIN-rail type L2/L4 Managed Gigabit PoE++ Switch family featuring PLANET intelligent PoE functions to improve the availability of critical business applications. It provides IPv6/IPv4 dual stack management and built-in L2/L4 Gigabit switching engine along with 8 10/100/1000BASE-T ports featuring 95-watt 802.3bt PoE++, 2 additional Gigabit copper ports and another 2 extra 100/1000BASE-X SFP fiber slots for data and video uplink. The IGS-4215-8UP2T2S is able to operate reliably, stably and quietly in any hardened environment without affecting its performance. It comes with a total power budget of up to 360 watts for different kinds of PoE applications and operating temperature ranging from -40 to 75 degrees C in a rugged IP30 metal housing.
- Key Features
- Specifications
- Applications
Physical Port
- 8 10/100/1000BASE-T Gigabit Ethernet RJ45 ports with IEEE 802.3bt PoE++ Injector function
- 2 10/100/1000BASE-T Gigabit Ethernet RJ45 ports
- Two 100/1000BASE-X SFP slots for SFP type auto detection
- One RJ45 console interface for basic management and setup
Power over Ethernet
- Complies with IEEE 802.3bt Power over Ethernet Plus Type-4 PSE
- Backward compatible with IEEE 802.3af/at PD device
- Up to 8 ports of IEEE 802.3af/802.3at/802.3bt PoE++ devices powered
- 360-watt PoE budget
- Supports PoE power up to 95 watts for each PoE port
- Auto detects powered device (PD)
- Circuit protection prevents power interference between ports
- Remote power feeding up to 100 meters in standard mode and 250m in extend mode
- PoE management
- Total PoE power budget control
- Per port PoE function enable/disable
- PoE port power feeding priority
- Per PoE port power limitation
- PD classification detection
- Intelligent PoE features
- PD alive check
- PoE schedule
Industrial Hardened Design
- 48~54V DC, redundant power with reverse polarity protection
- DIN-rail and wall-mount designs
- IP30 aluminum case
- Supports 6KV DC Ethernet ESD protection
- -40 to 75 degrees C operating temperature
Layer 2 Features
- Supports VLAN
- IEEE 802.1Q tagged VLAN
- Provider bridging (VLAN Q-in-Q, IEEE 802.1ad) support
- Protocol VLAN
- Voice VLAN
- Private VLAN (Protected port)
- Management VLAN
- GVRP
- Supports Spanning Tree Protocol
- IEEE 802.1D Spanning Tree Protocol (STP)
- IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)
- IEEE 802.1s Multiple Spanning Tree Protocol (MSTP), spanning tree by VLAN
- STP BPDU Guard, BPDU Filtering and BPDU Forwarding
- Supports Link Aggregation
- IEEE 802.3ad Link Aggregation Control Protocol (LACP)
- Cisco ether-channel (static trunk)
- Maximum 6 trunk groups, up to 8 ports per trunk group
- Provides port mirror (many-to-1)
- Loop protection to avoid broadcast loops
- Supports ERPS (Ethernet Ring Protection Switching)
- Link Layer Discovery Protocol (LLDP)
Quality of Service
- Ingress/Egress Rate Limit per port bandwidth control
- Traffic classification
- IEEE 802.1p CoS
- IP TCP/UDP port number
- Typical network application
- Strict priority and Weighted Round Robin (WRR) CoS policies
- Supports QoS and In/Out bandwidth control on each port
- Traffic-policing on the switch port
- DSCP remarking
Multicast
- Supports IPv4 IGMP snooping v2, v3
- Supports IPv6 MLD snooping v1, v2
- IGMP querier mode support
- IGMP snooping port filtering
- MLD snooping port filtering
Security
- Storm Control support
- Broadcast/ unknown multicast/unknown unicast
- Authentication
- IEEE 802.1X port-based network access authentication
- Built-in RADIUS client to cooperate with the RADIUS servers
- DHCP Relay and DHCP Option 82
- RADIUS/TACACS+ users access authentication
- Access Control List
- IPv4/IPv6 IP-based ACL
- IPv4/IPv6 IP-based ACE
- MAC-based ACL
- MAC-based ACE
- MAC Security
- Static MAC
- MAC filtering
- Port security for source MAC address entries filtering
- DHCP snooping to filter distrusted DHCP messages
- Dynamic ARP inspection discards ARP packets with invalid MAC address to IP address binding
- IP source guard prevents IP spoofing attacks
- DoS attack prevention
Management
- IPv4 and IPv6 dual stack management
- Switch Management Interface
- Web switch management
- Console/Telnet Command Line Interface
- SNMP v1 and v2c switch management
- SSHv2, TLSv1.2 and SNMP v3 secure access
- SNMP Management
- SNMP trap for interface Link Up and Link Down notification
- Four RMON groups (history, statistics, alarms and events)
- User privilege levels control
- Built-in Trivial File Transfer Protocol (TFTP) client
- Static and DHCP for IP address assignment
- System Maintenance
- Firmware upload/download via HTTP/TFTP
- Configuration upload/download through HTTP/TFTP
- Dual images
- Hardware reset button for system reboot or reset to factory default
- SNTP Network Time Protocol
- Network Diagnostic
- Cable diagnostics
- ICMPv6/ICMPv4 Remote Ping
- SFP-DDM (Digital Diagnostic Monitor)
- Link Layer Discovery Protocol (LLDP) Protocol and LLDP-MED
- Event message logging to remote syslog server
- PLANET Smart Discovery Utility for deployment management
- PLANET NMS system and CloudViewer for deployment management
| Hardware Specifications | |
|---|---|
| Copper Ports | Ten 10/100/1000BASE-T RJ45 auto-MDI/MDI-X ports (Ports 1 to 10) |
| PoE Injector Port | Eight ports with 802.3af/802.3at/802.3bt PoE++ injector function (Ports 1 to 8) |
| SFP Ports | Two 1000BASE-SX/LX/BX SFP interfaces (Ports 11 to 12) Compatible with 100BASE-FX SFP |
| Console | 1 x RS232-to-RJ45 serial port (115200,8, N, 1) |
| RAM | 128Mbytes |
| Flash Memory | 16Mbytes |
| Reset Button | < 5 sec: System reboot > 5 sec: Factory default |
| Connector | Removable 6-pin terminal block Pin 1/2 for Power 1 ; Pin 3/4 for fault alarm ; Pin 5/6 for Power 2 |
| Alarm | One relay output for power failure. Alarm relay current carry ability: 1A @ 24V AC |
| Power Requirements | 48~54V DC,8.5A (max.) (>52V DC for PoE++ output recommended) |
| Power Consumption/ Dissipation | System On:Max. 9.18 watts/31.3BTU PoE Full Loading: Max. 390 watts/1329.9BTU |
| Dimensions (W x D x H) | 76.8 x 107.3 x 152 mm |
| Weight | 1,091g |
| Enclosure | IP30 aluminum case |
| Installation | DIN-rail kit and wall-mount ear |
| ESD Protection | Contact Discharge 6KV DC Air Discharge 8KV DC |
| Surge Protection | 4KV DC |
| LED | System: Power 1 (Green) Power 2 (Green) Fault Alarm (Red) Ring (Green) R.O.( Green) Per 10/100/1000T RJ45 PoE++ Ports: 1000Mbps LNK/ACT (Green) 10/100Mbps LNK/ACT (Amber) 802.3bt PoE++-in-use x 1 (Green) 802.3at/af PoE-in-use x 1 (Amber) Per 10/100/1000T RJ45Ports:, 1000 LNK/ACT (Green) 10/100 LNK/ACT (Amber) Per SFP Interface: 1000 LNK/ACT (Green) 100 LNK/ACT (Amber) PoE Usage: 90W, 180W, 270W, 360W (Amber) |
| Switching Specifications | |
| Switch Architecture | Store-and-Forward |
| Switch Fabric | 24Gbps/non-blocking |
| Switch Throughput@64 bytes | 17.85Mpps |
| MAC Address Table | 8K entries |
| Shared Data Buffer | 4.1 megabits |
| Flow Control | IEEE 802.3x pause frame for full duplex Back pressure for half duplex |
| Jumbo Frame | 10 Kbytes |
| Power over Ethernet | |
| PoE Standard | IEEE 802.3bt PoE++ Type-4 |
| PoE Power Supply Type | End-span Mid-span BT |
| Power Pin Assignment | 802.3bt/UPoE: 1/2(-), 3/6(+),4/5(+), 7/8(-) 802.3at/PoE: End-span: 1/2(-), 3/6(+) 802.3at/PoE: Mid-span: 4/5(+), 7/8(-) |
| PoE Power Output | Per port 48V ~ 54V DC 802.3bt Type-4 mode: maximum 95 watts End-span mode: maximum 36 watts Mid-span mode: maximum 36 watts Force mode: maximum 95 watts |
| PoE Power Budget | Single power input: 240W maximum (depending on power input) Dual power input: 360W maximum (depending on power input) ※Dual power input must be the same as DC voltage, like dual 54V. |
| Number of 90W 802.3bt Type-4 PDs | 4 |
| Number of 60W 802.3bt Type-3 PDs | 6 |
| Number of 30W 802.3at Type-2 PDs | 8 |
| PoE Management Functions | |
| Enhanced PoE Mode | Standard/Legacy/Force |
| PoE Management | PD Alive Check Scheduled Power Recycling PoE Schedule PoE Usage Monitoring PoE Extension |
| Active PoE Device Live Detection | Yes |
| PoE Power Recycling | Yes, daily or predefined schedule |
| PoE Schedule | 4 schedule profiles |
| PoE Extend Mode | Yes, max. up to 250 meters |
| Layer 2 Functions | |
| Port Mirroring | TX/RX/Both Many-to-1 monitor Up to 4 sessions |
| VLAN | 802.1Q tagged VLAN 802.1ad Q-in-Q tunneling (VLAN stacking) Voice VLAN Protocol VLAN Private VLAN (Protected port) GVRP Management VLAN Up to 256 VLAN groups, out of 4094 VLAN IDs |
| Link Aggregation | IEEE 802.3ad LACP and static trunk Supports 6 groups with 8 ports per trunk |
| Spanning Tree Protocol | IEEE 802.1D Spanning Tree Protocol (STP) IEEE 802.1w Rapid Spanning Tree Protocol (RSTP) IEEE 802.1s Multiple Spanning Tree Protocol (MSTP) STP BPDU Guard, BPDU Filtering and BPDU Forwarding |
| IGMP Snooping | IPv4 IGMP snooping v2, v3 IGMP querier Up to 256 multicast groups |
| MLD Snooping | IPv6 MLD snooping v2, v3, up to 256 multicast groups |
| Access Control List | IPv4/IPv6 IP-based ACL/MAC-based ACL IPv4/IPv6 IP-based ACE/MAC-based ACE |
| QoS | 8 mapping IDs to 8 level priority queues Port number 802.1p priority DSCP/IP precedence of IPv4/IPv6 packets Traffic classification based, strict priority and WRR Ingress/Egress Rate Limit per port bandwidth control |
| Ring | Supports ERPS, and complies with ITU-T G.8032 Recovery time < 450ms |
| Security Functions | |
| Access Control List | IPv4/IPv6 IP-based ACL/MAC-based ACL IPv4/IPv6 IP-based ACE/MAC-based ACE Max. 256 ACL entries |
| Port Security | IEEE 802.1X – Port-based authentication Built-in RADIUS client to co-operate with RADIUS server RADIUS/TACACS+ user access authentication |
| MAC Security | IP-MAC port binding MAC filter Static MAC address, max. 256 static MAC entries |
| Enhanced Security | DHCP Snooping and DHCP Option82 STP BPDU guard, BPDU filtering and BPDU forwarding DoS attack prevention ARP inspection IP source guard |
| Management Functions | |
| Basic Management Interfaces | RS232 to RJ45 Console Web browser Telnet SNMP v1, v2c |
| Secure Management Interfaces | SSHv2, TLS v1.2, SNMP v3 |
| System Management | Firmware upgrade by HTTP/TFTP protocol through Ethernet network Configuration upload/download through HTTP/TFTP LLDP protocol SNTP PLANET Smart Discovery Utility PLANET NMS System/CloudViewer |
| Event Management | Remote/Local Syslog System log |
| SNMP MIBs | RFC 1213 MIB-II RFC 1215 Generic Traps RFC 1493 Bridge MIB RFC 2674 Bridge MIB Extensions RFC 2737 Entity MIB (Version 2) RFC 2819 RMON (1, 2, 3, 9) RFC 2863 Interface Group MIB RFC 3635 Ethernet-like MIB RFC 3621 Power Ethernet MIB |
| Standards Conformance | |
| Regulatory Compliance | FCC Part 15 Class A EN 55032 EN 55035 ICES-003 issue 7 CE |
| Stability Testing | IEC 60068-2-32 (free fall) IEC 60068-2-27 (shock) IEC 60068-2-6 (vibration) |
| Standards Compliance | IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX/100BASE-FX IEEE 802.3z Gigabit SX/LX IEEE 802.3ab Gigabit 1000BASE-T IEEE 802.3x Flow Control and Back Pressure IEEE 802.3ad Port Trunk with LACP IEEE 802.1D Spanning Tree Protocol IEEE 802.1w Rapid Spanning Tree Protocol IEEE 802.1s Multiple Spanning Tree Protocol IEEE 802.1p Class of Service IEEE 802.1Q VLAN Tagging IEEE 802.1x Port Authentication Network Control IEEE 802.1ab LLDP IEEE 802.3af Power over Ethernet IEEE 802.3at Power over Ethernet Plus IEEE 802.3az for Energy-Efficient Ethernet RFC 768 UDP RFC 783 TFTP RFC 791 IP RFC 792 ICMP RFC 2068 HTTP RFC 1112 IGMP v1 RFC 2236 IGMP v2 RFC 3376 IGMP v3 RFC 2710 MLD v1 RFC 3810 MLD v2 ITU G.8032 ERPS Ring |
| Environment | |
| Operating Temperature | -40 ~ 75 degrees C |
| Storage Temperature | -40 ~ 85 degrees C |
| Humidity | 5 ~ 95% (non-condensing) |